// SERVICES · INDUSTRIAL SECURITY
OT/ICS security assessment
Technical assessments of operational technology, industrial control systems, critical infrastructure and industrial connections, including the introduction of AI. We examine access paths, segmentation and dependencies within the operating constraints of your environment.
What we examine
- Access paths between office networks, remote access, vendor connections and the plant floor.
- Segmentation: whether the separation between zones holds in practice, not only on the network diagram.
- Dependencies: the systems, data flows and suppliers that production and safety rely on.
- AI in industrial environments: what an AI system connected to OT consumes, what it can reach and what changes when it is introduced.
Availability, physical consequences, long equipment lifecycles and vendor access set the limits of every assessment. Passive assessment and controlled testing are selected according to the environment and the agreed scope; passive assessment is an option where active testing is restricted.
Q-SAM: where systems sit, how they connect
The Quantropic Security Architecture Model maps the systems, data and AI models in scope across four deployment areas, each with three zones. Deployment areas are where a system runs, from your own high-security environment to the open Internet; zones are how strictly it is separated inside that area.
We assess the protection of each element and of the communication and access paths connecting them. Protection is scored from 0 to 100 and compared with the requirements your organisation defines; confidentiality, integrity and availability are evaluated separately. A weakness along a connection can affect the systems it reaches, and the map shows where. It helps compare changes to system placement, connections and controls before they are made.
From practice
Automotive: access paths from office systems to the shop floor. An assessment examined access paths between the office network and shop-floor systems, including KUKA welding robots. Testing demonstrated that manipulation of robot operation could compromise weld integrity. The findings led management to decide on changes to the architecture.
Chemical: data protection across international operations. Assessments across sites in Asia, the United States and Brazil examined risks of data leakage and manipulation, including remote laboratory environments. At one site, a USB keyboard attack enabled access to a Siemens HMI, which provided visibility into the company's wider international environment.
Both engagements were led by Rolf Schulz, who brings more than 30 years of experience in critical infrastructure, industrial and military security.
After the assessment
We explain the significance of each finding, its potential consequences and the changes that deserve priority. Our involvement can continue through architecture review, remediation and verification of agreed changes.
// CONTACT